Desc.
Power supply model number | SAW30A-xxx-yyyyzf , CGSW30A-xxx-yyyyII | |
---|---|---|
Output | DC voltage | 5V - 48V |
Rated Current | Max 3.5A | |
Current Range | 0-3.5A | |
Rated Power | 30W | |
Ripple & Noise | 200Vp-p Max | |
Voltage Tolerence | +/- 5% | |
Input | Voltage Range | 90-264V AC 50/60Hz |
Safety Standard | IEC 62368-1B / IEC 61558-2-16E / cUL1310 | |
Safety Certification | EN62368:UL/CB/CE/GS/EMC/LVD/RCM/KC/FCC/PSE/CCC | |
EN61558:CE/GS/CB/FCC/LVD/RCM cUL | ||
Operating temperature | 0-40 C° | |
Storage temperature | -20-60 C° | |
Hi-pot test | Primary To Secondary: 3000VAC 10mA 1 minute or 4000VDC 10mA 3 Sec | |
Burn-in test | 80% to 100% load, 40 C°± 5℃ for 4 hours | |
Dimension | 71.2x43.2x29mm | |
Length of DC cord | Optional(1.2m 1.5m 1.83m etc) | |
DC plug | Optional(5.5x2.5mm 5.5x2.1mm 3.5x1.35mm etc) | |
RoHS/Reach | Yes | |
Package | White box or plastic bag with outer carton | |
AC Fix PLUG (Interchangeable Plug) | USA/EU/UK/AU/CN or More | |
Desktop Type | Avalible | |
Efficiency Level | VI | |
load Regulation | +/-5% | |
Surge | Over 1 KV | |
No Load power consumption | < 0.1w | |
Protections | Short-circuit/OCP/OVP | |
Warranty | 3 Years |